หัวโพรบวัดรังสี BDBG-09 for Gamma Radiation Detection
Intelligent Detecting Unit of Gamma Radiation
-
Сonfirms to the CE standards
-
ТУ У 33.2-22362867-009:2004
-
Number U2071-05 in State Register for Measuring Instruments
-
State Sanitary-Epidemiological Conclusion # 05.03.02-04/90055 of November 19, 2010
-
Meets the requirements of IEC 61000-4-2:2008, IEC 61000-4-3:2007, IEC 61000-4-4:2008 standards.
Description:
BDBG-09 is used both within data panels and automated systems of radiation monitoring to measure ambient dose equivalent rate of gamma radiation.
A standard version of the detecting unit is produced with a built-in Geiger-Muller counter. A modification based on the scintillation detector is also available. Upon customer request the BDBG-09 housing can be made of duralumin or stainless steel. A special version of the detecting unit with waterproof housing has been developed for use in waterbodies and artificial reservoirs.
BDBG-09 detecting unit has been successfully used for many years at nuclear power plants in Ukraine, France, Bulgaria and Korea.
Purpose of Use:
-
Measurement of ambient dose equivalent rate (DER) of gamma radiation.
Features:
-
Data exchange between the detecting unit and the data display system through RS-485 interface.
-
Constant self-testing.
-
Indication of the statistical measurement error.
-
Ingress protection rating – ІР67.
-
Average service life of the detecting unit – not less than 10 years.
Specifications:
Measurement range of gamma radiation DER and main relative error |
0.05 µSv/h…10 Sv/h;(0.05 µSv/h…100 Sv/h on demand) |
±(15+2/H*(10))%, where H*(10) is a numeric value of measured DER equivalent to µSv/h |
Energy range of registered gamma and X-ray radiation and energy dependence |
MeV |
0.05…3.0; (0.05…1.25; ±25%) |
Integration time |
seconds |
2…420 |
Setup time of operating mode of the detecting unit |
min |
3 |
Operating supply voltage of the detecting unit from external power supply |
V |
7 … 13 |
Maximum current consumption of the detecting unit |
mA |
30 |
Operating temperature range |
°С |
-40…+60 |
Weight of the detecting unit without fastening elements |
kg |
0.5 |
Dimensions of the detecting unit without fastening elements |
mm |
170x60x60 |
Delivery Kit:
-
BDBG-09 detecting unit of gamma radiation;
-
corbel for vertical mounting of the unit;
-
cable connector;
-
technological kit used for testing of the detecting units (one kit per one consignment of the detecting units on demand), including: serial port adapter with power supply unit for а PC connection; technological cables (2 pcs.); technological software CD (1 pc.);
-
technical description and operating manual (one copy per one consignment of the detecting units);
-
logbook;
-
packing box.